Enter scan parameters in the fields below, and click "Estimate scan time"
to estimate the scan time:
A total area of 15.0 mm2 is scanned with 66600 points at 25 Hz
The flyscanning range is 4.995 mm, scanned in 333 intervals of 15 micrometers
The slow axis range is 3 mm, scanned in 200 steps of 15 micrometers
The flyscanning movement time is 2697s
The total overhead (slow axis movement and detector arming) is 613 s, corresponding to 21.5 %
Total estimated scan time is 0:55:10 (hh:mm:ss)